Cause: Belt stretching
Solution: Indicates system underbelted. Recalculate tension requirement.
Cause: Fabric instability
Solution: Check all environmental conditions that might affect fabric service life.
Cause: Water absorption
Solution: Consider replacing cotton or rayon with nylon or polyester fabrics.
Cause: Heat memory of synthetic fabrics
Solution: Double check environmental heat factors, available take-up, position of take-up on installation and cleaning procedures. Refer to technical or belt manufacturer.
Cause: Under belted
Solution: Recalculate tension requirement. Change belt recommendations or consider changing drive design.
Cause: Fabric instability
Solution: Check environmental conditions and consider replacing with nylon or polyester fabrics.
Cause: Excessive build-up on pulleys
Solution: Keep pulleys clean with routine maintenance or mechanical cleaning devices.
Cause: Excessive take-up force
Solution: Reduce tension to the point that belt will not slip or replace screw with automatic system.
Cause: Under belted
Solution: Recalculate tension requirement.
Cause: Fabric instability
Solution: Recheck environmental conditions and consider replacement with nylon or polyester fabrics.
Cause: Pulleys too small
Solution: Replace with larger pulleys.
Cause: Excessive pulley crown
Solution: Refer to CEMA Standard 402-1964 or check with technical of belt manufacturer.
Cause: Chemical attack
Solution: Check environmental conditions and refer to technical or belt manufacturer.
Cause: Improper slack side tension
Solution: Adjust take-up position. Consider lagging drive pulley and installing snub pulley to increase belt wrap on drive pulley.
Cause: In slider bed service-suction between belt and slider bed surface in presence of moisture
Solution: Weld 1/4" or 1/2" round rods to slider bed surface or perforate conveyor bed. Round off and smooth all surfaces in contact with belt.
Cause: Improper cover compound or type of surface of top cover.
Solution: Check with your distributor giving operational data and system profile.
Cause: Insufficient slack side tension
Solution: Adjust take-up position and consider increasing wrap of drive with snub pulley and lagging drive pulley.
Cause: Improper compound for service
Solution: Check environmental conditions-especially oil and solvents. Refer to belt manufacturer's complete operation and environmental data.
Cause: Slipping on drive pulley
Solution: Advance take-up pulley toward maximum position.
Cause: Under belted
Solution: Recalculate tension to select correct construction.
Cause: Undersize pulleys
Solution: Check all pulleys, especially high tension snub or reverse pulley.
Cause: Heat
Solution: Determine surface temperatures and check against rated resistance of compound in service.
Cause: Weather or age cracking
Solution: Check rated resistance of compound in service.
Cause: Undersize pulley
Solution:Check minimum pulley recommendations of belt in service. Replace pulleys or change belt recommendations.
Cause: Underbelted
Solution: Recalculate tension. Change belt recommendation or alter drive design.
Cause: Shrinkage
Solution: Heat or chemicals causing loss of plasticisers and then elasticity.